p440ar firmware. O/S VMWare 5. p440ar firmware

 
 O/S VMWare 5p440ar firmware  What else? P440ar firmware version? The server is only a few

Troubleshooting Update. This will help ensure the destination controller can properly understand all metadata written to the headers on the source controller. 0. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. may have older product names and model numbers that differ from current models. 1038-1 and Firmware version affected: 1. 7, and configured with any of the following HPE Smart Array Controllers with smartpqi Driver version affected: 1. 2) It is possible to work around the above limitation by adding a registry key. 56, a few days ago. Any HPE ProLiant Gen10 server or HPE Synergy Gen10 Compute Module running VMware ESXi 6. 15(B) 2023-07-06. Internal Storage Devices One of the followingThe minimum supported OS for the HP Flexfabric 10Gb 2-port 526 FLR-SFP+ adapter is 12. 04), upgrading iLO 4 to 2. HPE Smart Array P440 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. It features eight internal physical links and delivers increased server. 60(B). Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. We have a slightly confusing situation with a Smart Array P400 storage controller with the 512mb battery backed accelerator addon on an HP DL380 server. , and then select the flash file. Please power off the hardware, remove power. 03. Learn more about its features, specifications, firmware updates, and LED indicators from the official HPE support document. HPE Smart Array P440ar Controller cabling. Learn how to update the iLO firmware of your HPE server using the HPE Service Pack for ProLiant (SPP) and the Smart Update Manager (SUM) tool. Nov 9, 2017. 65-0 in the VMware Compatibility Guide): Printer Setup, Software & Drivers; Printing Errors or Lights & Stuck Print Jobs; DesignJet, Large Format Printers & Digital Press; Sprocket; Samsung; Printers Knowledge Base; Printer Wireless, Networking & Internet; Printer Ink Cartridges & Print Quality; Printer Paper Jams & Feed Issues; Desktops Desktop Software and How To Questions Re: How do I download firmware . rpm 7. This document provides the user guide for the HP Array Configuration Utility (ACU) CLI, a tool that allows users to configure and manage HP Smart Array controllers and logical drives. The HPE Smart Array P440 Controller is a 12Gb/s SAS RAID controller that offers high performance, scalability and data protection for HPE ProLiant Gen9 servers and Apollo. Important: Firmware version 4. This solution uses HP Smart Update Manager (HP SUM) as the deployment tool. 摘要. M. Product Bulletin, research Hewlett Packard. 32 Firmware Supports Online Firmware Activation: False Wait for Cache Room: Disabled. ) OP . To install the host using the HP ESXi 6. Now I have an alarm on the storage controller. Reply. The FW for Win2008x64 does not say that OS is not correct. Here we can see that RUNNING_FIRM_REV is already 6. Other than that, enter your serial in and see if its under warranty still. ESXi showed me a warning on Smart Array P440ar about the firmware version: 3. 26. HPE 1. 9. HPE Smart Array P440ar Controller. HPE ProLiant DL388 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 0 Version: 4. 00 Embedded media initialization failed due to media write-verify test failure. 750450-001. If the active firmware image becomes corrupt, the controller will use the redundant firmware image and continue operating. In this video I'm preparing my storage server by updating the HP P420 firmware using a storage pack. 0 build-5310538. Learn more at the Official Hewlett Packard Enterprise. Install the host using HP's custom ESXi 6. When the update tool is run it will indicate firmware versions currently installed on the server. Re: Smart Array P440ar in Embedded Slot - The cache is permanently disabled Hi, Yes I have already tried to re-enabled the cache settings but problem remain so let me replace the controller card since cache memory is embedded and confirm you the final status soon. Showing 1-10 of 5291) For P440ar check the firmware version - it has to be 4. So all those customers get these warnings after a major upgrade (6. Hi there, few days ago i installed my test system with esxi 6. Learn more about its features, specifications and compatibility from this webpage. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. Reboot the server and press F9 at post to enter into system utilities --> Embedded Applications --> Firmware update --> Select installed Smart Array. Choose Exit and Launch HP Storage Administrator. HPE DL380 Gen9 P440ar/H240ar Riser 2 SAS expander kit. if yes, may be you should check the SD-card firmware in the ilo UI. Open Power ISO software and click on New --> hard disc image (last option) Now add firmware file "HPE_luxor. 10. " Select the appropriate operating system. Hello guys. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The HPE Smart Array P440ar Controller is a flexible and reliable SAS RAID controller that supports up to 26 internal device drives and delivers enhanced performance, data. All this with FreeBSD 13. 02, and 4. HPE ProLiant DL388 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. . The device driver and the controller should work together without timeouts after file systems are mounted. 62 (or later), logical drives may become inaccessible. Click the Flash button. then upgrade the firmware to lastest version. 2. Smart Array P440ar in Slot 0 (Embedded) Note: Predictive Spare Activation Mode is enabled, physical drives. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. ~ # esxcli hpssacli cmd -q “controller slot=0 modify hbamode=on forced". 96W Smart Storage Battery - For DL/ML/SL Generation 9 series of servers - One battery pack provides flash back write cache (FBWC) for all the drive controllers in the server - Connects to the system I/O board, 145mm (5. Yes it is a custom HPE/PMC Sierra design, > microsemi > MicroChip. 00Firmware packages in this document have a specified Minimum Supported Version, Current Supported Version, and Maximum Supported Version. 04. ESXi 6. 1331820 driver. 4 Ghz - HP SmartArray P440ar (firmware version 7. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. ago. 52. Background Initialization. Software - System Management. It was working fine, then I have updated the HP Smart Array P440ar firmware, rebooted the host (twice), and the same command which was working before. As mentioned earlier, with modern firmware, you can use any disks you want. 3) 4GB NAND NOTE:. View Profile View Forum Posts View Forum Threads Visit Homepage. . Hey all, I have an ESXi 5. 102 HP operating. Victor 0 08-08-2016, 08:24 AM #2. If the active firmware image becomes corrupt, the controller will use the redundant firmware image and continue operating. Overview 6 Using HP SSA over other configuration utilities provides the following benefits: • GUI, CLI, and Scripting interfaces are available. HPE ProLiant Gen9 Server - HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter: Resetting to Factory Defaults. Firmware - Storage Controller. Integrated Systems. Aviso Smart Array P440ar. Software Details - System ROM Flash Binary - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers | HPE Support. -Check current firmware-Locate newest firmware from vendor-Upload firmware-Reboot Open-E DSS V7Storage software that gets the job done: · Data Protection and Recovery Software. This is HP’s official website that will help automatically detect and download the correct drivers free of cost for your HP Computing and Printing products for Windows and Mac operating system. fw" in same, Now save the file as an img format and mount the same to flash further. The next piece of firmware to execute might actually be the firmware of the Smart Array P440ar Controller. 88?) what does 0 mean? I searching the whole HPE download center and did not found it. Intelligent Provisioning prepares the system for installing "off-the-shelf" and Hewlett Packard Enterprise branded versions of operating system software and integrates optimized ProLiant server support software. Can I just purchase the controller and replace it. 04), upgrading iLO 4 to 2. Welcome to Software and Drivers for . QuickSpecs HPE Smart Array P440 Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 1 x8 internal port o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries • 4 GiBytes. Top. could it be the Smart Array P440ar needs a firmware update? It's V4. Showing. thanks, Kev If you are looking for the latest software for your HPE Smart Array P440 Controller, you can download it from this webpage. This document provides step-by-step instructions, screenshots, and troubleshooting tips for common issues. The firmware blocks the following operations if reconstruction is in progress: Any descriptor command (DCMD) related to configuration changes. Locked post. The update fixes a. Product: Smart Array P440ar. The HPE Smart Array P440 Controller is a 12Gb/s SAS RAID controller that offers high performance, scalability and data protection for HPE ProLiant Gen9 servers and Apollo systems. Buenos Dias, Comunidad. The latency is shown by the HPE Dual MicroSD where is Esxi running on it. 9 • Red Hat Enterprise Linux 7. 1 The HP Dynamic Smart Array B110i/B120i/B320i controller driver for Ubuntu 12. 00: Recommended: Firmware - Storage Controller: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p,. 52, Hardware. The secondary problem is that you're still dependent on the RAID card firmware surviving, and ZFS is known to place a huge workload on it - a RAID card torture test. The HP smart array P440ar Raid controller failed on a server and I can no longer see the logical drives. HPE Smart Array P440 Controller. Oct 24, 2016. Doing these steps did get the server back online. 2TB SAS 12G Enterprise 10 K SFF. HPE Smart Array P840ar Controller cabling. RoHS. Select "get drivers, software, and firmware. Choose a different product . HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. And 2 Intel DC S3710 with firmware G2010110, also in original trays. Upgrade to at least 6. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically. Firmware Version: bc 1. Proactive notifications; Service Pack for ProLiant. 2. Procedure Download the. ProLiant DL360 Gen9 with HP Smart Array P440ar Controller. This is a general issue with vSAN: Hardware vendors organising that their controllers etc. TechNet; Products; IT Resources; Downloads; Training; Support. 2. 0. Navigate to the Virtual SAN cluster in the vSphere Web Client. HPE Smart Storage Administrator: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. I did not try the b140i which is on the mainboard. HPE ProLiant Servers - Running ESXi 6. Format new array and restore data from tape backup. bin. HPE Technology Service Portfolio. 02 or later, the power must be cycled by removing the power cord from the power source, waiting 10 seconds, and then replacing the power cord to activate this important CPLD update. 02 (or later). VGA is Radeon, and complains about the firmware missing (no acceleration, reduced 2D performance). The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. It features eight internal physical links and delivers increased server uptime by. O/S VMWare 5. Product Bulletin, research Hewlett Packard. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. Get product support and knowledge from the open source experts. 1 The HP Dynamic Smart Array B110i/B120i/B320i controller driver for Ubuntu 12. Download Software. Release Device Driver Firmware Package Version Firmware Version Queue Depth Driver Type vSAN Type FeaturesAnd points out a problem with HP's software. 88 Firmware Dependency: None. 52 is included in the Service Pack for ProLiant (SPP) Version 2016. This x64 Smart Component provides firmware for the following storage controllers: Smart Array H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440. 24SFF drives at the front and 2SFF drives at the rear of the server — Connect the P440ar controller cables to the 12G SAS Expander port 1 and port 2. 0; using interactive mode, deselect the firmware version 4. Deploys and manages HPE Secure Encryption, a data protection solution. The p440ar's had an issue where I had to physically unseat them after a power drain, boot the system once without, and then shutdown and power drain again before reinstalling the controller once more. 0. VMWare is ESXi 6. Any time the operating system is running During POST, before the operating system is installed Where the utility can be used Any machine that uses aHPE Smart Array P244br Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Universal media bay cabling. My team 's got refurbished HP DL380 Gen9 boxes, all coming with a P440ar controller and a 12LFF front drive cage. HPE Technology Service Portfolio. 0 Kudos admin. The update fixes a critical issue that may cause data loss or corruption. BenefitsUpdate the server firmware ("Methods for updating the firmware" on page 12). And 2 Intel DC S3710 with firmware G2010110, also in original trays. The easiest way to do this on HP servers is to download HP Service Pack for Proliant. Any HPE ProLiant Gen10 server or HPE Synergy Gen10 Compute Module running VMware ESXi 6. exe) - Operating System : Windows Server 2012 R2 - SmartArray Driver : HPE ProLiant SmartArray HPCISSS3 controller driver version 106. The HPE Secure Encryption, a data encryption solution with a smart array controller designed for HP Gen 9 servers, protects mission-critical and sensitive data. 15(B) 2023-07-06. Firmware Upgrades of DL 380 Gen9 . Click the Flash button. This item: HP Smart Array P440ar/2GB with FBWC Storage Controller Plug-in Card (726736-B21) $181. 881457-B21. 10. P840 on the bootable, P440ar on the other 2. Remove drives used in data array and hot spare, and label with their positions. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. 88 Firmware Dependency: None. Download PDF. 7 on its firmware site. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. Use AHCI SATA mode instead. If you try to change RAID card working mode from RAID to HBA mode now, you will find that the RAID array disk will disappear from lsblk. Creates and sets up HPE SmartCache to accelerate. After conducting a very thorough investigation, HPE and the vendor are confident that they have identified the root cause of the issues and on August 11, 2020, HPE released HPE. 5. An example of a SAS HBA is Supermicro SAS2LP-MV8. 3 The HP Dynamic Smart Array B110i/B120i/B320i controller for Ubuntu 14. Software running on this is limited to working on CentOS 5. Put host in MM, from ilo of ESXi in support mode (Alt+F1) execute the following. For this reason, when first upgrading firmware on an embedded controller from an older version to version 4. Use the HP Smart Storage Utilities for Linux to modify the RAID configuration within the host OS. 04,. Hewlett Packard Enterprise Support CenterHPE Smart Array P410 Controller - How to Change the RAID. The installation is complete. What else? P440ar firmware version? The server is only a few. The following process was used: Shut down server. Software, firmware, and utilities. This x64 Smart Component provides firmware for the following storage controllers: Smart Array H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440. I've installed a recent Debian 10 Buster system on to the server, which is HPE DL360 Gen9. 32 ROM firmware: 8. 4. 5. (embedded RAID) and a controller (version 2. Put host in MM, from ilo of ESXi in support mode (Alt+F1) execute the following. This will help ensure the destination controller can properly understand all metadata written to the headers on the source controller. 0. Showing 1 of 1. In this server, HPE SSA can be accessed in. The only way to shut the noise was to put windows. HPE Smart Array P440ar Controller cabling. 1. Firmware | SATA Storage Disk. Hewlett Packard. 64 (cp037982. Software and Firmware versioning info from CIM Providers. HPE Smart Array P244br Controller, HPE Smart Array P440 Controller, HPE Smart Array P440ar Controller, HPE Smart Array P441 Controller, HPE Smart Array P840 Controller, HPE. el ‎20-12-2019 09:40 AM. Second option is to download and run HP SUM (Smart Update Manager) on any other computer/server on the same network and as a target add your core server. HPE Smart Array P440ar Controller. Detailed step by step RAID 5 configuration of Smart Array P440ar controller on HP DL380 G9 server, step by step video tutorial available from the live serverArray P440ar, P440, P441, H240nr, P240nr, P542D, and P741m controllers have completed FIPS 140-2 Level 1 validation (certificate #2506). TechNet; Products; IT Resources; Downloads; Training; Support. Type. It seens have a firmware version 6. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. 12G SAS Expander Card. Installing an M. 74-1OEM. Download specific drivers. Servers for Internet of Things. Server mode; Smart Update ManagerWe would like to show you a description here but the site won’t allow us. Drum roll. The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for specific HPE ProLiant Gen9 rack and tower servers. ESXi showed me a warning on Smart Array P440ar about the firmware version: 3. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. Learn more about SUM. Server mode; Smart Update ManagerChose Embedded RAID 1: Smart Array P440ar controller. Controller: Smart Array P440ar in Embedded Slot Device: Logical Drive 2 Severity: Warning Message: This logical drive has Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface Analysis (ARM) scan. Just because you bought it used, doesn't mean it wasn't still under warranty. In case you haven't got Linux, you can use a Linux Live CD. HPE Smart Array P440ar Controller - LED Indicators. Intelligent Provisioning provides installation help for Microsoft Windows, Red Hat and SUSE Linux, and VMware operating systems. The document covers the installation, syntax, commands, and examples of using the ACU CLI. So I installed latest version 4. LG Spirit LTEH440V. Detected operating system: Choose a different OS . 0. 0. The HPE Smart Array P440ar Controller delivers 12 Gb/s SAS connectivity on HP ProLiant Gen9 Servers when connected to 12 Gb/s internal storage devices for increased performance in messaging, database or general server applications. 5 or VMware ESXi 6. Information on this page is applicable for current generation Intel® RAID & Storage products. نکته مهم در مورد ویژگی آنلاین کنترلر P440ar. So I installed latest version 4. 60 I have noticed significant through put reduction on the P212 with the tape library. 65(B) (also denoted as 1. 0, which we would have brought up to 6. Products. 5 RHEL. This is my first time doing this, so lets see how it goes!Unpack the server shipping carton, and locate the materials and documentation necessary for installing the server. I have the P440ar connected to the risers on the front of the system, and I'm starting off the P840 6. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. 00 Last Recommended or Critical Version: 6. When activated with a registered license key, SAAP 1. 4 TB - hot-swap - 2. 1038-1 and Firmware version affected: 1. My attempts to fix said issue were: upgrading the smart array controller (P440ar) firmware to the latest version (5. 5 on the host above. Use the HP Smart Storage Utilities for Linux to modify the RAID configuration within the host OS. You will also find the release notes. 00. Try installing driver hpsa version 6. To proceed, upgrade the firmware in steps. If you have a legacy product, please visit. Showing. I. Are you looking for the latest software and firmware updates for your HPE Smart Array P440ar Controller? Download them from this webpage, where you can also find installation instructions, release notes, and compatibility information. 1. The bad disk so rebuild failedHPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The HP ProLiant DL380 Gen9 server was released a few weeks ago in late 2014. Updating the BIOS when Windows Does Not Start - Notebook Computers with Windows 8, 7. 5. In this server, HPE SSA can be accessed in. Doing these steps did get the server back online. Open Power ISO software and click on New --> hard disc image (last option) Now add firmware file "HPE_luxor. 5. Note: Flashing firmware to a SAS expander will likely not work when the expander is connected to a SAS RAID controller because that controller might hide all devices behind it from the OS. 04. Siga estos pasos para intentar resolver: 1 - Conecte el disco en el servidor Gen9 y reinicie el servidor; 2 - Presione F10 para acceder a Intelligent Provisioning; 3 - Seleccione la opción "Perform Maintenance"; 4 - Seleccione la opción Smart Storage Administrator SSA; 5 - Seleccione la Smart Array P440ar; 6 - Haga clic en el botón. Reboot the server and press F9 at post to enter into system utilities --> Embedded Applications --> Firmware update --> Select installed Smart Array. Last Recommended or Critical Version: 6. 2 SSD enablement board. Now that’s a little bit. Flashing blue The drive carrier firmware is being updated or requires an update. Product Support Software & Drivers Warranty Check Enhanced Support Services Education and Training Product Return and Recycling OEM Solutions. Before upgrading, read this important information. 67K views 7 years ago. Hewlett Packard Enterprise support portal for business, enterprise and IT users. 4. HPE Smart Array P440 Controller Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard. 60 if not 7. It had nothing to do with the P440AR. Showing 9 of 9. Open all. Obtain Software. Before putting server in the production, it’s always smart to update firmwares of all the components in the box, like P440ar RAID controller’s firmware, Bios, Power Management and so on. error: enumInstances No data received from server [root@esxi:~] vmware -vl. · Data Archive and Migration Software. 5 update 3 installed with two Windows 2012R2 VM's on themThe HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for specific HPE ProLiant Gen9 rack and tower servers. Hmmm. Explore the new digital customer experience engagement platform. On-Line Spares: There is no limit to the number of spare drives that can be installed prior to drive failure. 4TB 10000RPM 2. Data Availability, Protection and Retention. I've tried h730 [and h740] in a test rig, and they seem to. /ssacli ctrl slot=5 lk. 74-1OEM. 06 is not supported for vSAN on P440 nor P440ar, nor is driver 6. 18. 5 will work if you add the driver disk available. 00 : HPE NS204i OS Boot Device - Critical Firmware Update Required to Prevent Potential Data Inconsistency Issues During Volume Rebuild HP ProLiantサーバー用HP Smart アレイコントローラー. exe) - Operating System : Windows Server 2012 R2 - SmartArray Driver : HPE ProLiant SmartArray HPCISSS3 controller driver version 106. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. 24 Serial Number: *snip* Rebuild Priority: Medium. Problematic firmwares include 2. Off = Deactivated *When all four LEDs described in this table flash simultaneously, a power fault has occurred. iLO4 has been updated and the new P440ar is running the latest firmware, any advice here please would be appreciated. 04) And the same for the Wellsburg AHCI controller. P440ar VSMART ARRAY Cntrl (RAID Controller) firmware-smartarray-ea3138d8e8-7. ko driver to be outdated as I need a minimum version from September 2014. Product Support Software & Drivers Warranty Check Enhanced Support Services Education and Training Product Return and Recycling OEM Solutions Validate Equipment Parts. IT Financing and Investment Services. 02_B0, I find it stange it has no issue with the 16TB EXOS drives which are also quite new, so I don't think that's the issue. Obtain Software. Option 2 sounded much better. thanks. 5 to 6. 09. VMware ESXi 6. may have older product names and model numbers that differ from current models.